Saad / Syahrom / Harun Wear Prediction on Total Ankle Replacement
2016
ISBN: 978-3-319-21723-9
Verlag: Springer International Publishing
Format: PDF
Kopierschutz: 1 - PDF Watermark
Effect of Design Parameters
E-Book, Englisch, 63 Seiten, eBook
Reihe: SpringerBriefs in Computational Mechanics
ISBN: 978-3-319-21723-9
Verlag: Springer International Publishing
Format: PDF
Kopierschutz: 1 - PDF Watermark
This book develops and analyses computational wear simulations of the total ankle replacement for the stance phase of gait cycle. The emphasis is put on the relevant design parameters. The book presents a model consisting of three components; tibial, bearing and talar representing their physiological functions.
Zielgruppe
Research
Autoren/Hrsg.
Weitere Infos & Material
1;Preface;7
2;Acknowledgments;8
3;Contents;9
4;Abstract;11
5;1 Introduction;12
5.1;1.1 Ankle Joint Anatomy;13
5.1.1;1.1.1 Ankle Biomechanics;15
5.1.2;1.1.2 Loading on the Ankle;16
5.1.3;1.1.3 Kinematics of the Ankle;18
5.2;1.2 Ankle Joint Problems that Lead to Surgical Treatment;18
5.3;1.3 Ankle Joint Treatment;20
5.3.1;1.3.1 Ankle Fusion;21
5.3.2;1.3.2 Total Ankle Replacement (TAR);21
5.4;1.4 Total Ankle Replacement (TAR);23
5.4.1;1.4.1 Agility TAR (DePuy, Warsaw, iN, USA);23
5.4.2;1.4.2 Scandinavian Total Ankle Replacement (STAR) (Waldmar Link, Hamburg, Germany);24
5.4.3;1.4.3 Buechel-Pappas (BP) TAR;25
5.4.4;1.4.4 Bologna, Oxford Total Ankle Replacement (BOX);26
5.5;1.5 Complications;26
5.6;References;27
6;2 Contact Pressure of Total Ankle Replacement (TAR);29
6.1;Abstract;29
6.2;2.1 Geometric Model;29
6.3;2.2 Finite Element Analysis;30
6.3.1;2.2.1 Development of Finite Element Analysis of Gait Cycle;31
6.3.1.1;2.2.1.1 Create Model;32
6.3.1.2;2.2.1.2 Define Materials;32
6.3.1.3;2.2.1.3 Configure Analysis;33
6.3.1.4;2.2.1.4 Apply Loads and Boundary Conditions;33
6.3.1.5;2.2.1.5 Mesh the Model;33
6.3.1.6;2.2.1.6 Run Analysis;34
6.4;2.3 Contact Analysis;35
6.4.1;2.3.1 Contact Pressure of Total Ankle Replacement (TAR);36
6.5;2.4 Sliding Distance;37
6.6;2.5 Validity of Contact Analysis;38
6.6.1;2.5.1 Mesh Sensitivity Test;39
6.6.2;2.5.2 Contact Analysis;40
6.7;References;41
7;3 Wear of Total Ankle Replacement (TAR);43
7.1;Abstract;43
7.2;3.1 Fundamental of Wear Modelling;43
7.2.1;3.1.1 Wear of Total Ankle Replacement (TAR);44
7.3;3.2 Wear Model of Total Ankle Replacement (TAR);45
7.4;3.3 Update Contact Geometry of Total Ankle Replacement (TAR);46
7.5;3.4 Wear Sensitivity Study;48
7.6;References;50
8;4 Effect of Design Parameter Towards Wear Generation;52
8.1;Abstract;52
8.2;4.1 Parametric Study;52
8.2.1;4.1.1 Thickness of Meniscal Bearing;52
8.2.2;4.1.2 Radial Contact of Meniscal Bearing;56
8.2.2.1;4.1.2.1 Conformable Radius of Curvature of Meniscal Bearing;56
8.2.2.2;4.1.2.2 Unconformable Radius of Curvature of Meniscal Bearing;59
8.3;References;61
9;5 Conclusion;63
Introduction.- Contact Pressure of Total Ankle Replacement.- Wear of Total Ankle Replacement.- Effect of Design Parameter toward wear generation.- Summary.




